In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

7MTT MetroCluster Precheck Error 88020: Details error 16035 "admin password not set"

Views:
106
Visibility:
Public
Votes:
0
Category:
7-mode-transition-tool
Specialty:
core
Last Updated:

Applies to

  • 7-Mode Transition Tool (7MTT)
  • Clustered Data ONTAP

Issue

  • 7MTT MetroCluter Precheck fails with error 88020:

Failed to check whether the target cluster is part of MetroCluster configuration because 7-Mode Transition Tool failed to retrieve the storage system information from the target cluster. Rerun the operation. If issue persists, contact technical support.

  • Error code 16035 is also seen under "Failure Details" section:

The admin password is not set. Use the "security login password" command to set the password, then try the command again.