Skip to main content

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

NetApp Knowledge Base

"Chassis Power Fault detected" messages in ConfigAdvisor

Views:
84
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • FAS8300 / FAS8700 / AFF A400
  • 1600W PSU
  • All ONTAP versions
  • BMC firmware 13.6 or lower
  • ActiveIQ ConfigAdvisor

Issue

  • ActiveIQ ConfigAdvisor reports an alert of Chassis Power Fault detected with further details of Chassis power supply 2 and 1 have failed, been removed, or turned-off
  • System is up and running and no PSU failure is noticed upon physical inspection
  • system node environment sensors show -name PSU* will only display sensors PSU1 Vin Type and PSU2 Vin Type as failed

cluster::> system node environment sensors show -name PSU*
Node Sensor                 State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
node01
     PSU1 VIN              failed
                                      
     PSU1 VOUT             normal
                                    12012 mV     11336    11440   12948   13156
     PSU1 Curr IIN         normal
                                      832 mA         0        -    9984   12012
     PSU1 IOUT             normal
                                    12000 mA         0        -  130000  132000
     PSU1 PIN              normal
                                   170400 mW      7100    14200 1611700 1796300
     PSU1 POUT             normal
                                   149100 mW      7100    14200 1611700 1796300
     PSU1 Inlet            normal
                                       22 C          0        -      58      63
     PSU1 Hot              normal
                                       32 C          0        -     100     105
     PSU1 FB Hot           normal
                                       29 C          0        -     100     105
     PSU1 FAN              normal
                                     4500 RPM      800     1200       -       -
     PSU2 VIN              failed
                                   
     PSU2 VOUT             normal
                                    12012 mV     11336    11440   12948   13156
     PSU2 Curr IIN         normal
                                      988 mA         0        -    9984   12012
     PSU2 IOUT             normal
                                    15000 mA         0        -  130000  132000
     PSU2 PIN              normal
                                   198800 mW      7100    14200 1611700 1796300
     PSU2 POUT             normal
                                   177500 mW      7100    14200 1611700 1796300
     PSU2 Inlet            normal
                                       24 C          0        -      58      63
     PSU2 Hot              normal
                                       33 C          0        -     100     105
     PSU2 FB Hot           normal
                                       30 C          0        -     100     105
     PSU2 FAN              normal
                                     4500 RPM      800     1200       -       -
     PSU1 Present          normal
                                      PRESENT
     PSU2 Present          normal
                                      PRESENT
     PSU1                  normal
                                         GOOD
     PSU2                  normal
                                         GOOD

 