In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

mNode intermittently stops reporting during stuck HCC FW upgrade

Views:
54
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
hci
Last Updated:

Applies to

  • NetApp Element management node (mNode)
  • Ongoing (firmware) upgrade via Hybric Cloud Control (HCC)
  • Upgrade in pending or stuck status for extended period of time

Issue

  • /var/log folder running out of space due to large sf-urtfi-init.info file
  • mNode reboots due to insufficient space in /var/log
  • last reboot command on mNode will show frequent reboots
  • Reporting to Active IQ intermittently breaks as containers are not coming back up immediately due to /var/log running full
  • mNode kernel reporting about space issues
    kernel: [    2.103330] pci 0000:00:18.2: BAR 13: no space for [io  size 0x1000]
    kernel: [    2.103333] pci 0000:00:17.7: BAR 13: no space for [io  size 0x1000]
    kernel: [    2.103336] pci 0000:00:17.6: BAR 13: no space for [io  size 0x1000]
  • False positive error status about already upgraded systems do not get resolved
    • Upgrade error
    • Unable to detect
Scan to view the article on your device