Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Is it possible to change the MTU post install on NetApp HCI Systems

Views:
233
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
hci
Last Updated:

Applies to

  • NetApp HCI
  • NetApp Deployment Engine (NDE)
  • Maximum Transmission Unit (MTU)

Answer

The MTU size setting on all HCI nodes can be changed to the default 1500 value after NetApp Deployment Engine (NDE) has completed deploying the system, however, it is not supported by NDE itself.

If the MTU size setting were to be changed to 1500, NDE's EasyScale utility would not be able to add new compute or storage nodes to existing VMware ESXi or NetApp Element Software clusters.

Additional Information

additionalInformation_text

 