Issue

  • One drive is failed and shown under Cluster > Drives > Failed section on the Cluster UI
  • NetApp SolidFire Active IQ and Cluster UI shows 1 drive(s) with state: "DriveMissing" driveID: <ID> alert with the error code driveFailed
  • iEEvent entry at the time of the issue with a similar output can be found in Events
    • { "throwFile": "shared/BasicFile.cpp", "throwFunction": "size_t solidfire::BasicFile::ReadRaw(uint8_t*, off_t, size_t, solidfire::AllowReadTruncation)", "throwLine": 272, "whatString": "/dev/sd<ID>: Input/output error", "exceptionCode": "xFileReadFailed", "currentStack": "", "streamDetails": 1 }
    • { "throwFile": "serviceshared/DiskDataDiskModel.cpp", "throwFunction": "solidfire::DiskFileScanner::LoadFileInfo()::<lambda(solidfire::FileNumber)>::<lambda()>", "throwLine": 204, "whatString": "IO Error reading segment header errno=5 result=0", "exceptionCode": "xSegmentHeaderReadIOError", "currentStack": "", "streamDetails": 1 }

 