Skip to main content

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey. 

NetApp Knowledge Base

'bnx2x_attn_int_deassertedX - FATAL error from CFC' on SolidFire nodes

Views:
322
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

Applies to

  • NetApp SolidFire storage nodes
  • NetApp Element Software (11.7 and below)
  • NIC driver bnx2x version 1.712.30-0

Issue

Kernel files (kern.log*) and (sys.log) running full with: 

  • [bnx2x_attn_int_deasserted(X):4219(eth<X>)]CFC hw attention 0x2
  • [bnx2x: [bnx2x_attn_int_deasserted(X):(XXXX)(eth<X>)]FATAL error from CFC
     

Typically this will result in the following error in NetApp SolidFire Active IQ:

  • fileSystemCapacityLow - File System /var/log has <X>% free space (below 5%). Please contact support.

Additional (possible) errors if the issue is not addressed in a timely manner:

  • nodeOffline - The SolidFire Application cannot communicate with node ID <X>.
  • unresponsiveService - A master service is not responding.
  • memoryUsageThreshold - System memory is very low. Adding additional nodes or manually purging deleted volumes may help reduce memory usage.
  • authenticationServiceFault - Unable to determine status of Element Auth container on node 2. Please contact support if this problem persists.

 