In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Multiple drives failed when a volume is starting IAF

Views:
115
Visibility:
Public
Votes:
0
Category:
e-series-santricity-os-controller-software
Specialty:
esg
Last Updated:

Applies to

  • NetApp SANtricity OS earlier than 11.70.1.GA
  • Immediate Available Format (IAF)

Issue

  • A volume is created and mapped to a host.

A:7/18/21, 9:56:26 PM (21:56:26) 2713 520f Create volume-to-LUN mapping - Volume 1
A:7/18/21, 9:56:10 PM (21:56:10) 2712 5023 Controller return status/function call for requested operation - Shelf 99, Bay A
----> RPC function : 0x0007 = createVolume
----> Return code  : 0x0001 = ok
A:7/18/21, 9:56:10 PM (21:56:10) 2711 5002 Create volume - Volume 1

  • Data Assurance errors and Unreadable sectors are logged against the volume when IAF is starting.

A:7/20/21, 7:21:47 PM (19:21:47) 2844 225a Immediate availability initialization (IAF) started on volume - Volume 1
A:7/20/21, 7:21:47 PM (19:21:47) 2843 6700 Unreadable sector(s) detected data loss occurred - Volume 1 - LBA: 0x14ef66000 <--CRITICAL
----> Physical Drive in Tray 99 Slot 12, LBA: 0x563d39800

A:7/20/21, 7:21:46 PM (19:21:46) 2831 201e VDD repair started - Shelf 99, Bay A - SSID: 0, Devnum: 0x01003b
A:7/20/21, 7:21:46 PM (19:21:46) 2830 2062 Data assurance mismatch detected - probable cause is data on drive - Volume 1 - ioType: DST_IN, hwPIStatus: GUARD_ERROR, swPIStatus: NOT_CHECKED, Host ID: 65535, LBA: 0x14ef66100
----> Expected Guard:0x0000, AppTag:0x0000, RefTag:0x00000000
----> Found    Guard:0x0000, AppTag:0x0000, RefTag:0x00000000

  • Unreadable sector database is full.

A:7/20/21, 7:21:47 PM (19:21:47) 2851 6703 Overflow in unreadable sector database - Volume 1 <--CRITICAL

  • Multiple drives are failed and volumes are failed.

A:7/20/21, 7:21:54 PM (19:21:54) 2959 226c Drive failure - Shelf 99, Drawer 3, Bay 11 - Cause: 3 = Write failure; Drive WWN: WWN1WWN1WWN1WWN1; SN: SN1SN1SN1SN1 <--CRITICAL

A:7/20/21, 7:21:54 PM (19:21:54) 2955 2250 Volume failure - Volume 1 <--CRITICAL

A:7/20/21, 7:21:52 PM (19:21:52) 2866 226c Drive failure - Shelf 99, Drawer 2, Bay 11 - Cause: 3 = Write failure; Drive WWN: WWN2WWN2WWN2WWN2; SN: SN2SN2SN2SN2 <--CRITICAL

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support