Skip to main content
NetApp Knowledge Base

SVM DR update/initialize fails with error "Unable to generate baseline for table sis"

Views:
1,194
Visibility:
Public
Votes:
1
Category:
snapmirror
Specialty:
dp
Last Updated:

Applies to

  • ONTAP 9.6
  • ONTAP 9.7
  • ONTAP 9.8

Issue

  • SVM DR update/initialize fails with the following error:

Failed to generate baseline. Reason: Unable to generate baseline for table sis. The system might be busy, retry the operation after some time.
Execute "snapmirror show -destination-vserver <DESTINATION-VSERVER> -fields last-transfer-error,unhealthy-reason -expand" to check if the constituent volumes have encountered errors.

  • /etc/log/mlog/crs.log shows the following error:

[kern_crs:info:5583] 0x809262d00: 0: ERR: crs_internal: Baseline fetch failed for table sis - Loop detected in next() for table sis. 
Next on ""vserver name" "volume path"" returned ""vserver name" "volume path"". {in write_object_rows_to_file() at src/tables/crsa/crs_internal.cc:2599}
[kern_crs:info:5583] 0x80925ce00: 0: ERR: crs_streams: Unable to generate a local baseline for 6a368d57-a987-11ea-8b97-d039ea14dafc 
{in generate_a_local_baseline_imp() at src/tables/crsa/crs_stream_operational_attributes.cc:1262}

  • No evidence in snapmirror-audit.log for SVM DR update

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.