Skip to main content
NetApp Knowledge Base

SVM DR update fails with error "Unable to generate baseline for table sis"

Views:
106
Visibility:
Public
Votes:
0
Category:
snapmirror
Specialty:
dp
Last Updated:

Applies to

  • ONTAP 9.6
  • ONTAP 9.7P11

Issue

  • SVM DR update fails with the following error:

Failed to generate baseline. Reason: Unable to generate baseline for table sis. The system might be busy, retry the operation after some time.
Execute "snapmirror show -destination-vserver <DESTINATION-VSERVER> -fields last-transfer-error,unhealthy-reason -expand" to check if the constituent volumes have encountered errors.

  • /etc/log/mlog/crs.log shows the following error:

[kern_crs:info:5583] 0x809262d00: 0: ERR: crs_internal: Baseline fetch failed for table sis - Loop detected in next() for table sis. 
Next on ""vserver name" "volume path"" returned ""vserver name" "volume path"". {in write_object_rows_to_file() at src/tables/crsa/crs_internal.cc:2599}
[kern_crs:info:5583] 0x80925ce00: 0: ERR: crs_streams: Unable to generate a local baseline for 6a368d57-a987-11ea-8b97-d039ea14dafc 
{in generate_a_local_baseline_imp() at src/tables/crsa/crs_stream_operational_attributes.cc:1262}

  • No evidence in snapmirror-audit.log for SVM DR update

 