SVM DR resync failed to apply the source Vserver configuration on the destination
Applies to
- ONTAP 9
- SVM DR resync
Issue
Error appliers when running SVM DR resync:
Failed to apply the source Vserver configuration. Reason: Apply failed for Object: sis Method: baseline. Reason: Failed to modify efficiency configuration for volume "Dst_Vol" of Vserver "Dst_SVM": Cannot change the efficiency policy from "auto" because there is an active "auto" background efficiency operation on the volume. Use the "volume efficiency status" command to view the status of background efficiency operation on the volume. Use the "volume efficiency stop" command to issue stop on the running operation. If there is an active efficiency operation then use the "volume efficiency stop -all true -vserver "Dst_SVM" -volume "Dst_Vol" command to stop all efficiency operations on the volume "Dst_Vol".
Execute "snapmirror show -destination-vserver Dst_SVM -fields last-transfer-error,unhealthy-reason -expand" to check if the constituent volumes have encountered errors.