Skip to main content

NetApp_Insight_2020.png 

NetApp Knowledgebase

SVM-DR Failed to modify efficiency configuration

Views:
53
Visibility:
Public
Votes:
0
Category:
snapmirror
Specialty:
dp
Last Updated:

Applies to

  • ONTAP 9.x
  • SnapMirror
  • SVM-DR

Issue

  • SnapMirror update/resync fails with:

Failed to apply the source Vserver configuration.

Reason: Failed to modify efficiency configuration for volume "<volume>" of Vserver "<SVM>": Compression cannot be disabled when inline compression or incompressible data detection is enabled on the volume. Disable inline compression and retry the command. If there are active SIS operations then use the "volume efficiency stop -all true -vserver * -volume *" command to stop all efficiency operations on all volumes in the cluster. Failed to apply the source Vserver configuration.

Reason: Apply failed for Object: sis Method: baseline.

Reason: Failed to modify efficiency configuration for volume "<Volume>" of Vserver "<SVM>": Compression cannot be disabled when inline compression or incompressible data detection is enabled on the volume. Disable inline compression and retry the command. If there are active SIS operations then use the "volume efficiency stop -all true -vserver * -volume *" command to stop all efficiency operations on all volumes in the cluster. 

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support