In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Is the vserver migrate start command to migrate SVM part of SVM-DR supported ?

Views:
88
Visibility:
Public
Votes:
0
Category:
snapmirror
Specialty:
dp
Last Updated:

Applies to

SVM DR

Answer

According the SVM data mobility overview under Unsupported features it is visible:

  • iSCSI workloads
  • IPv6 LIFs
  • SVM migration when the source cluster’s Onboard Key Manager (OKM) has Common Criteria (CC) mode enabled
  • SVM peering, SnapMirror, data protection volume
  • SAN, NVMe over fiber, CIFS, VSCAN, NFS v4.0, vStorage, S3 replication
  • Auditing
  • NDMP
  • VIP/BGP LIF
  • IPsec policy
  • Anti-ransomware
  • Qtree, Quota
  • SVM-DR
  • External Key Manager at the destination cluster
  • SnapMirror
  • SnapLock
  • FlexGroups
  • FlexCache
  • FabricPools
  • Flash Pool aggregates
  • MetroCluster
  • System Manager
  • Virtual Storage Console for VMware vSphere (VSC is part of the ONTAP Tools for VMware vSphere virtual appliance beginning with VSC 7.0.)
  • Volume clones
  • FAS arrays
  • Load-sharing mirrors
  • Cloud Volumes ONTAP