Skip to main content
NetApp Knowledge Base

Can I use  Fan-out to migrate an Identity preserve SVM-DR to a new Cluster?

Views:
1,803
Visibility:
Public
Votes:
2
Category:
snapmirror
Specialty:
dp
Last Updated:

Applies to

  • ONTAP 9.3 and earlier
  • SVM-DR
  • SnapMirror

Answer

Workaround for ONTAP 9.3 and earlier:

  1. Use volume SnapMirror to migrate the data to an SVM of the New Cluster
  2. Break and release the original SVM-DR
  3. Convert the new volume SnapMirror to SVM-DR

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.