Skip to main content
NetApp Knowledgebase

SCV restores fail when multiple clones of LUN are found

Views:
122
Visibility:
Public
Votes:
0
Category:
snapcenter
Specialty:
snapx
Last Updated:

Applies to

  • SnapCenter Server 
  • SnapCenter Plugin for vMWARE vSphere [SCV]
  • VMWARE Management Object Browser [MOB]
  • NetApp Data Broker [NDB]

Issue

  • SCV restores fail with "More than one clone of LUN with UUID:5c6c54f4-83dcd92a-ad89-0025b501a000 found. Aborting mount because this is not supported. Check and verify whether multiple clones of the LUN are present which are not yet resolved as VMFS datastores"

2020-04-10T10:27:51.0000160-05:00 DEBUG VSC com.netapp.aegis.vsphere.DatastoreService [JobId:XXXXX] DatastoreUtils: Invoking Rescan VMFS on ESX HOST <ESX hostname>
2020-04-10T10:28:04.0000170-05:00 DEBUG VSC com.netapp.aegis.vsphere.DatastoreService DatastoreUtils: Completed Rescan VMFS on ESX HOST <ESX hostname>
2020-04-10T10:28:04.0000170-05:00 DEBUG VSC com.netapp.aegis.mount.VmfsMountStrategy vscDatastoretoMount size: 1
2020-04-10T10:28:24.0000101-05:00 DEBUG VSC com.netapp.aegis.mount.VmfsMountStrategy Total number of unresolved volumes: 1
2020-04-10T10:28:24.0000101-05:00 DEBUG VSC com.netapp.aegis.mount.VmfsMountStrategy Finding the matching Host Unresolved Volume
2020-04-10T10:28:24.0000101-05:00 DEBUG VSC com.netapp.aegis.mount.VmfsMountStrategy Finding: Comparing original datastore UUID <UUID> with unresolved VMFS volume's UUID <UUID>
2020-04-10T10:28:24.0000101-05:00 DEBUG VSC com.netapp.aegis.mount.VmfsMountStrategy Uuid Match Found for Host Unresolved volume: <UUID>
2020-04-10T10:28:24.0000101-05:00 DEBUG VSC com.netapp.aegis.mount.VmfsMountStrategy Adding entry in the map
2020-04-10T10:28:24.0000101-05:00 DEBUG VSC com.netapp.aegis.mount.VmfsMountStrategy Total Number of entries in DatastoreVolumeMap: 1
2020-04-10T10:28:24.0000101-05:00 DEBUG VSC com.netapp.aegis.mount.VmfsMountStrategy Total Number of Extents found for the volume is 2
2020-04-10T10:28:24.0000101-05:00 ERROR VSC com.netapp.aegis.mount.VmfsMountStrategy [JobId:XXXXX] More than one clone of LUN with UUID:<UUID> found. Aborting mount because this is not supported. Check and verify whether multiple clones of the LUN are present which are not yet resolved as VMFS datastores
2020-04-10T10:28:24.0000101-05:00 WARN  VSC com.netapp.aegis.mount.VmfsMountStrategy [JobId:XXXXX] Error during mounting datastore : []

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support

 

 

  • Was this article helpful?