In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

SCV quiescing error in backup does not trigger a warning email notification

Views:
52
Visibility:
Public
Votes:
0
Category:
snapcenter
Specialty:
snapx
Last Updated:

Applies to

SnapCenter Plug-in for VMware vSphere (SCV) 4.5

Issue

  • With a quiescing error, SCV fails to send a warning notification email as it believes the job was successful
  • Quiescing error in wfe_<jobID>.log is:

    Unable to quiesce on SCV: Exception occurred when quiescing virtual machines: VM_Name, VM_Name.Please check 'Create virtu al machine snapshot' task on vSphere Web Client or SnapCenter Plug-in for VMware vSphere logs for detailed error message
     
  • The email entry in the wfe_<jobID>.log is:

    DEBUG hbmena33.hugoboss.com --- [nio-8080-exec-4] c.n.w.a.EmailActivity                    : EmailActivity CanExecute Started
    DEBUG hbmena33.hugoboss.com --- [nio-8080-exec-4] c.n.w.a.EmailActivity                    : Email preference is on error or warning but job was successful; not sending email

  • Issue happens if the email preferences are set to Error & Warnings or Always

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support