NDMP Veeam DMA connects successfully but NdmpGetFileSystemInfo requests times out

Views:
408
Visibility:
Public
Votes:
0
Category:
ndmp
Specialty:
dp
Last Updated:

Applies to

  • ONTAP 9
  • Veeam Backup and Replication
  • Network Data Management Protocol (NDMP)
  • Maximum Transmission Unit (MTU) 9000

Issue

  • Veeam successfully connects and authenticates with the ONTAP 9 cluster but the NDMP connection times out with no error seen on the ONTAP 9 cluster
  • Veeam Error:

Error [cluster1-NDMP] Failed to rescan NDMP server Error: Failed to call RPC function 'NdmpGetFileSystemInfo': Timed out to process command: 'Get file system information 'NDMP error:NDMP_TIMEOUT_ERR.

  • NDMP Log confirms the FS Info is been send:

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: DMA<<S V4 sequence=7 (0x7)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: Time_stamp=0x60a7abd0 (May 21 14:47:12 2021)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: message type=1 (NDMP4_MESSAGE_REPLY)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: message_code=0x105 (NDMP4_CONFIG_GET_FS_INFO)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: reply_sequence=5 (0x5)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: error_code=0 (NDMP4_NO_ERR)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info_len=13 (0xd)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[0] unsupported=0x0 ()

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[0] fs_type='WAFL' fs_logical='/SVM1/VOL1' fs_physical=''

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[0] total_size=107374182400 (0x1900000000) used_size=100000 (0xf422db000) avail_size=100000 (0x9bdd25000) total_inodes=100000 (0x2f7fff) used_inodes=144 (0x90) fs_status='online'

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[0] fs_env_len=3 (0x3)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[0] fs_env[0] name='LOCAL' value='Y'

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[0] fs_env[1] name='TYPE' value='WAFL'

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[0] fs_env[2] name='VSERVER_ROOT' value='N'

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[1] unsupported=0x0 ()

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[1] fs_type='WAFL' fs_logical='/SVM1/VOL2' fs_physical=''

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[1] total_size=132607115264 (0x1ee0000000) used_size=100000 (0x19dc221000) avail_size=100000 (0x503ddf000) total_inodes=100000 (0x1e66658) used_inodes=471693 (0x7328d) fs_status='online'

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[1] fs_env_len=3 (0x3)

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[1] fs_env[0] name='LOCAL' value='Y'

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[1] fs_env[1] name='TYPE' value='WAFL'

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[1] fs_env[2] name='VSERVER_ROOT' value='N'

Fri May 21 2021 14:47:12 +02:00 [kern_ndmpd:info:5151] [53607] DEBUG: fs_info[2] unsupported=0x0 ()

  • Packet Traces revealed the Cluster send the  FS_info to the DMA but this packet never gets acknowledged before session closure

NDMPFSINFO.jpg

  • At the end  we observed a [PSH,ACK] form the DMA  which confirmed that the DMA is still at ACK number 357 from before the FS_INFO packet

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.