fcvi.qlgc.qpErr: FC-VI adapter: FCVI driver on port x received QP Error
Applies to
- ONTAP 9
- Fabric Attached MetroCluster
- Brocade storage switches
Issue
- Following errors are reported in event logs:
fcvi.qlgc.qpErr: FC-VI adapter: FCVI driver on port X received QP Error. QP name = Control, QP
index = 0x1, VI state = Error(state code = 0x3), sub-error = Message ID error(OOD)(error code = 0x6). Remote node's system id =x. This error has occured X times.
7/25/2023 02:22:09 NodeA_1 ERROR fcvi.qlgc.ioErr: FC-VI adapter: FCVI driver on port 5a received IO error. Status = FW detected response error(status code = 0x121), FCVI opcode = Write Request(0x1), QP name = WAFL, QP index = 2, Remote node's system id = xxxxxxx.
- Brocade switch reports errors on the affected port in the output of
portterrshow
command:
porterrshow :
frames enc crc crc too enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt out c3 fail sync sig tx rx err err
2: 2.1g 1.1g 0 0 0 0 0 64 2 0 2 0 0 0 0 0 0
3: 2.3g 352.2m 0 4 4 0 0 8.7k 28.7k 1 28.6k 0 0 8.7k 5 1.2k 0
- Brocade switch reports low TX power for the affected port in the output of
sfpshow
command:
sfpshow -all :
=============
Port 3:
=============
Current: 10.450 mAmps
Voltage: 3306.4 mVolts
RX Power: -2.7 dBm (534.3uW)
TX Power: -6.3 dBm (234.6 uW)