In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

What do the MetroCluster HealthMonitoring alerts mean?

Views:
811
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

 

Applies to

  • MetroCluster
  • ONTAP 9
  • Health Monitoring

Answer

Alert Description
NoISLPresentAlert This alert indicates that there is no InterSwitch Link (ISL) present between the Fibre Channel switches in between the sites of the MetroCluster.
StorageBridgeUnreachable (in-band) Indicates an ATTO FibreBridge is no longer reachable via the management network (FC).
StorageBridgeUnreachable (snmp) Indicates an ATTO FibreBridge is no longer reachable via the management network (Ethernet).
Bridge is incorrectly configured Indicates a miscabling of the FC-SAS Bridge.
StorageBridgePortDown Indicates a link from the FC port of the bridge to the switch or controller is not working correctly
Bridge Port is offline Indicates a misconfiguration of the FC-SAS Bridge or a cable problem
FabricSwitchUnreachable This alert indicated that one or more of the MetroCluster Fibre Channel switches is no longer reachable via the Ethernet network.
FabricSwitchPowerFail A power supply of the MetroCluster backend FibreChannel switch has a failed or a the power is interrupted

Additional Information

Verify the system risks for your MetroCluster using the ActiveIQ tool

 