Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Switchback failing - the online status of the replication units in the cluster could not be verified

Views:
106
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster
  • Intercluster
  • Switchback failing
  • mtu mismatch between clusters

Issue

Switchback is failing after an unexpected switchover.

Metrocluster Operation Show reports:

ClusterA::> metrocluster operation show
  Operation: switchback
      State: failed
 Start Time: dd/mm/yyyy hh:mm:ss
   End Time: dd/mm/yyyy hh:mm:ss
     Errors: Failed to set up the node and cluster components for the switchback operation.
             ClusterA (fatal): The MetroCluster DR operation was terminated because the online status of the replication units in the cluster could not be verified. Run the (privilege: advanced) "cluster ring show" command to display the status of the replication units. Try the MetroCluster DR operation again when each replication unit's "online" field shows either "master" or "secondary".

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support