In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Option 6 resets ha-config from mcc or mccip to ha during boot_recovery process in 4-node MetroCluster

Views:
192
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • ONTAP 9
  • AFF A400
  • FAS8300
  • AFF A800
  • 4-Node Metrocluster FC
  • 4-Node Metrocluster IP

Issue

  • During a maintenance that requires the boot_recovery procedure to be performed (ARL headswap, boot device replacement) on an AFF A400 or FAS8300 running 9.7.X in a 4-node Metrocluster configuration, the backup configuration file must be restored onto the new boot media prior to booting back into ONTAP on the affected node.
  • It is noted that attempts to restore the VARFS backup configuration file using option 6 at the special boot menu fails.
  • You may see similar console messages appear as below in a 4-node Metrocluster FC configuation.
Jun 13 08:09:04 [Node1:fci.adapter.error:notice]: Fibre Channel adapter driver encountered error "Either the platform does not support this type of FC/FCVI adapter, or the platform supports the adapter but the chassis and controller variables are not set correctly." on adapter 2a.
Jun 13 08:09:04 [Node1:fci.adapter.error:notice]: Fibre Channel adapter driver encountered error "Either the platform does not support this type of FC/FCVI adapter, or the platform supports the adapter but the chassis and controller variables are not set correctly." on adapter 2b.
Jun 13 08:09:29 [Node1:scsitarget.slifct.fwAutoBoot:notice]: FC target HBA 1c firmware version updated from 11.4.277.0 to 12.2.390.0. The controller will be rebooted automatically to enable the new HBA firmware.
Rebooting after updating Emulex FC firmware.

 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support