Skip to main content
NetApp Knowledge Base

Node reports StorageFCAdapterFault_Alert for down or unused FC ports

Views:
274
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • FAS, AFF
  • Clustered ONTAP 8.3
  • ONTAP 9 and later
  • MetroCluster

Issue

  • The node sends AutoSupport alerts for StorageFCAdapterFault for down FC ports after every reboot.
  • Alert can be seen from clustershell as follows:

cluster::> system health alert show
               Node: <nodename>
           Resource: 4d
           Severity: Major
    Indication Time: Sat Aug 15 13:05:58 2020
           Suppress: false
        Acknowledge: false
     Probable Cause: FC initiator adapter 4d is at fault.
    Possible Effect: Resiliency of backend storage is compromised.
 Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
                     2. Verify the operational status of the FC initiator
                     adapter by using the command "system node run -node
                     local -command storage show adapter".

 