ONTAP 9
MetroCluster

Issue

The network interface show output on each cluster reports that the home port for a LIF on a DR Vserver is not the same interface as that used on the source cluster for this Vserver.

clusterA::> network interface show
  (network interface show)
            Logical    Status     Network            Current       Current Is
Vserver     Interface  Admin/Oper Address/Mask       Node          Port    Home
----------- ---------- ---------- ------------------ ------------- ------- ----
vserver
            lif1         up/up    10.10.100.10/24    clusterA-01    e0c     true
            lif2         up/up    10.10.100.11/24    clusterA-02    e0d     true
            lif4         up/up    10.10.100.12/24    clusterA-02    vlan-11 true

                 
clusterB::> network interface show
  (network interface show)
            Logical    Status     Network            Current       Current Is
Vserver     Interface  Admin/Oper Address/Mask       Node          Port    Home
----------- ---------- ---------- ------------------ ------------- ------- ----                                        
vserver-mc
            lif1         up/down  10.10.100.10/24    clusterB-02   e0e     true
            lif2         up/down  10.10.100.11/24    clusterB-01   e0c     true
            lif4         up/down  10.10.100.12/24    clusterB-01   vlan-22 true

 

 

 

 