Skip to main content
NetApp Knowledge Base

MetroCluster FC LIFs offline after switchover / switchback

Views:
410
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • Single Brocade Director SAN Switch
  • MetroCluster
  • ONTAP 9

Issue

After a switchover, the Disaster Recovery (DR) Sites FC LIFs are offline. 

During switchover, the FC LIF on the DR site logs in to the switch.

This is being refused by the switch, as it thinks the LIF on the Disaster Site is still up.

Node

FCP target 0g reported a port configuration change. FDISC RJT - FDISC failed because a LS_RJT was received for virtual port

Switch log

NPIV port 7/18 has same Port WWN as old port 7/38 with pid 0x32d641 as part of duplicate Port WWN detection policy.

 

 

 

 