ConfigAdvisor reports one of the following messages:

  • Switch Fabric does not contain the correct number of switches, one switch may be down, fabric is segmented, or too many switches seen
  • No FCVI zone in fabric for switches found
  • FCVI port is part of more than one zone
  • FCVI zones in fabric for switches does not contain all FCVI ports of the DrGroup
  • FCVI zone in fabric for switches has one or more FCVI ports represented with their WWN
  • FCVI zone in fabric for switches are not a QoS zone with priority 'high'.
  • FCVI zone in fabric for switches does contain one or more non-FCVI ports.
  • Storage zone in fabric for switches contain one or more ports that are not a Storage HBA and not a FibreBridge.
  • Storage zone in fabric for switches are incorrect and contain too many storage initiator ports.
  • Storage zone in fabric for switches are incorrect and contain not enough storage initiator ports.
  • Storage zone in fabric for switches are incorrect and contain too many FibreBridge ports
  • Storage zone in fabric for switches have one or more ports represented with their WWN.
  • No Storage zone in fabric for switches found.
  • Storage zoning configuration on Switch is not expected Storage zone.
  • Traffic Isolation (TI) zone configuration found on switch, TI is not supported in this configuration.
  • Storage zone in fabric for switches contain or more ports that are not a Storage initiator and not a target array port.
  • Storage zone in fabric for switches are and contain too many target array ports
  • Defined zone and effective zone do not match.
  • Zone is defined and not member of a configuration
  • Zone is defined but not active

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.