Local disks shown as missing and data in a 4 node Fabric MetroCluster
Applies to
- MetroCluster FC
- ONTAP 9.5
- Multiple Missing Disk
Issue
Communication issue after a power outage
- Multiple local disk from different shelves went missing only on 1 node
- Locally on the node the command
aggr status -f
display's several disks as missing.
Example:
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------------------- ---- ---- ---- ----- ---------- ---- ------------- ----------------
missing clu01-sw01:8.126L113 2c 20 8 FC:A 0 SAS 10000 560000/1146880000 560208/1147307696
missing clu01-sw01:8.126L115 2a 20 10 FC:A 0 SAS 10000 560000/1146880000 560208/1147307696
- The command "
aggr show
" or "disk show
" no errors are seen. - "
sysconfig -r
" display's several disks as missing and data
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------------------ ---- ---- ---- ----- ---------- ---- ------------- ----------------
data clu01-sw01:8.126L113 2c 20 8 FC:A 0 SAS 10000 560000/1146880000 560208/1147307696
data clu01-sw01:8.126L115 2a 20 10 FC:A 0 SAS 10000 560000/1146880000 560208/1147307696
- The disks are shown at the same time as
missing
anddata
orspare
in 1 node and also as data or spare on the HA Partner - Disk replacement does not help
- Power cycle of the disks does not help