Issue

There are a combination of FC-VI adapter disconnection errors and transport errors in the ems-log when accessing disks at the remote site:

[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = RAID, QP index = 3, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = MISC, QP index = 4, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = STREAM, QP index = 5, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = DRSOM_HB, QP index = 6, Remote node's system id = 123456789. 
[node1: ispfcvi2500_main1: fcvi.qlgc.ioErr:error]: FC-VI adapter: FCVI driver on port 1a received IO error. Status = FW detected response error(status code = 0x121), FCVI opcode = Write Request(0x1), QP name = RAID, QP index = 11, Remote node's system id = 123456789.
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = STREAM, QP index = 13, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = DRSOM_HB, QP index = 14, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = DRC_KILL, QP index = 15, Remote node's system id = 123456789. 

[node1: isp2400_timeout_2: fci.device.quiesce:debug]: Adapter 5a encountered a command timeout on Disk device REMOTE_FAB1_SW1:6.126 (0x06070600) LUN 22 cdb 0x2a:5a93b808:01f8 retry: 0 Quiescing the device.
[node1: isp2400_timeout_2: fci.device.timeout:debug]: HBA 5a encountered a device timeout on Disk device REMOTE_FAB1_SW1:6.126 (0x06070600) LUN 30 cdb 0x2a:5a93b818:01e8 retry: 0

 

The Brocade Switches report that one or more ISL interfaces reset:

2020/12/15-19:58:38, [C3-1023], 317, CHASSIS, WARNING, Brocade6505, Single RDY/Frame Loss detected and recovered on Slot 0,Port 8(12) rdy(0x1)/frame(0x0).

2020/12/15-19:58:38, [C3-1040], 318, CHASSIS, WARNING, Brocade6505, Multi RDY/Frame Loss detected on Slot 0, Port 8

2020/12/15-19:58:38, [C3-1014], 319, CHASSIS, WARNING, Brocade6505, Link Reset on Port S0,P10

 