Skip to main content
NetApp Knowledgebase

FabricSwitchUnreachable_Alert

Views:
114
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • Fabric MetroCluster
  • Brocade switches

Issue

  • A FabricSwitchUnreachable_Alert autosupport is triggered.
  • One or more of the ISL ports are G-Ports, and don't show as connected to the switch at the other site:

Example:

switchshow        :
switchName:    SiteB-Switch01
...

Index Port Address  Media Speed   State       Proto
==================================================
...
  22  22   021600   id    8G       Online     FC  LS G-Port
...

  • Only one switch is listed in the output of fabricshow:

Example:

fabricshow        :
Switch ID   Worldwide Name          Enet IP Addr    FC IP Addr      Name
-------------------------------------------------------------------------
  2: fffc02 XX:XX:XX:XX:XX:XX:XX:XX 10.20.30.40     40.30.20.10     >"SiteB-Switch01"

 