FC-AL LINK_FAILURE reported by stretch MetroCluster nodes
Applies to
- Stretch MetroCluster
- ONTAP 9
- FAS8200
- X1133A FC Adapter in slot 1
- ATTO FB7500N/7600N
Issue
- An autosupport is triggered from one (or both) of the nodes titled
FC-AL LINK_FAILURE
- The FC port that reports the error is in a
<DOWN>
state
Example:
slot 1: FC Host Adapter 1a (Emulex XE201 rev. 48, <DOWN>) Board name: 111-02455 Serial Number: ABCDEFGHIJ Firmware rev: 12.0.378.1 Host Port Id: N/A FC Node Name: 2:000:000000:000000 FC Port Name: 1:000:000000:000000 Link Data Rate: N/A
- There is a significant number of errors reported by the ATTO bridge
Example:
get FCPortErrors all
; Fibre Channel Error Counts
; Port | Link Failures | Sync Loss | Signal Loss | Invalid Tx | Invalid CRC
;==========================================================================
1 1051711 1795435 80860 14901579 0
2 1052319 1792284 79121 22508820 0