In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

ESXi hosts may lose connection to LUNs after MetroCluster switchover/switchback due to Cisco flogi settings

Views:
142
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • ONTAP 9
  • Cisco SAN switches
  • NX-OS 8.1 and later

Issue

  • When doing an MCC switchover or switchback, hosts may lose connection to LUNs
  • ESXi hosts accessing boot LUNs may need to be rebooted to recover LUN access
  • Otherwise it may be necessary to disable and reenable the switch ports the LIFs log in to

 