FOS-817953 is triggered by the use of the command network fcp zone show. This command does not query MetroCluster backend switches but only frontend SAN switches. 

Configuration details in a MetroCluster backend configuration are received via SNMP not via the network fcp zone show command. 

MetroCluster backend switches are not exposed to Brocade Defect FOS-817953.