Issue

  • After an ATTO bridge is rebooted, multiple disks are reported as missing and fail
Example:

Thu Sep 23 17:10:19 +0300 [fsrumogcsh0151: disk_server_1: disk.IO.status:debug]: params: {'deviceName': 'FC-Sw-A1:2.126L6', 'returnCode': '2', 'pathRetryCount': '0', 'adapterStatus': '0xd', 'cdb': 'XXXXX', 'basicTimeout': '9', 'iASCQ': '0x0', 'iSenseKey': '0x0', 'sSenseCode': '', 'ETime': '6866', 'iASC': '0x0', 'victimRetryCount': '14', 'sSenseKey': 'SCSI:no sense', 'targetStatus': '0x0', 'disk_information': 'Disk FC-Sw-A1:2.126L6 Shelf 0 Bay 5 [NETAPP   X371_S164A960ATE NA53] S/N [XXXXX] UID [00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'retryCount': '1', 'pathsTried': '0', 'timeoutRetryCount': '1'}
Thu Sep 23 17:10:19 +0300 [fsrumogcsh0151: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_data1/plex0/rg0/FC-Sw-A2:3.126L40 Shelf 0 Bay 13 [NETAPP   X371_S164A960ATE NA53] S/N [XXXXX] UID [00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Thu Sep 23 17:10:19 +0300 [fsrumogcsh0151: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr_data1/plex0/rg0/FC-Sw-A2:3.126L41 Shelf 0 Bay 14 [NETAPP   X371_S164A960ATE NA53] S/N [XXXXX] UID [00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.

 

  • One or more plexes are reported as failed

Example:

Thu Sep 23 17:10:19 +0300 [fsrumogcsh0151: config_thread: raid.rg.degraded:notice]: : Raid group /aggr_data1/plex0/rg0 is degraded
Thu Sep 23 17:10:19 +0300 [fsrumogcsh0151: config_thread: raid.vol.mirror.degraded:alert]: Aggregate aggr_data1 is mirrored and one plex has failed. It is no longer protected by mirroring.
Thu Sep 23 17:10:19 +0300 [fsrumogcsh0151: config_thread: callhome.syncm.plex:alert]: Call home for SYNCMIRROR PLEX FAILED

  • The corresponding plex fails and the RAID group is degraded

Example:

Aggregate aggr_data1 (online, raid_dp, mirror degraded, fast zeroed) (block checksums)

  Plex /aggr_data1/plex0 (offline, failed, inactive, pool0)
    RAID group /aggr_data1/plex0/rg0 (partial, block checksums)

      RAID Disk    Device                        HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------    ------                        ------------- ---- ---- ---- ----- --------------    --------------
      dparity     FC-Sw-A1:2.126L1        1c    0   0   FC:A   0   SSD   N/A 915465/1874872832 915715/1875385008 
      parity      FC-Sw-A2:2.126L2        1b    0   1   FC:A   0   SSD   N/A 915465/1874872832 915715/1875385008 
      data        FAILED                            N/A                        915465/ -
      data        FAILED                            N/A                        915465/ -
      data        FAILED                            N/A                        915465/ -
      data        FAILED                            N/A                        915465/ -
      data        FC-Sw-A1:3.126L47       1c    0   20  FC:B   0   SSD   N/A 915465/1874872832 915715/1875385008 
      data        FC-Sw-A1:3.126L48       1a    0   21  FC:B   0   SSD   N/A 915465/1874872832 915715/1875385008 
      data        FC-Sw-A2:2.126L23       1b    0   22  FC:A   0   SSD   N/A 915465/1874872832 915715/1875385008 
      data        FC-Sw-A1:3.126L50       1a    0   23  FC:B   0   SSD   N/A 915465/1874872832 915715/1875385008
      Raid group is missing 4 disks.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.