Skip to main content
NetApp Knowledge Base

DR partner NVLog mirroring is not online during headswap procedure

Views:
96
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • Fabric MetroCluster
  • ONTAP 9
  • Headswap from AFF-A300 to AFF-A400

Issue

  • After finalizing the first switchback after completing the headswap for the first site in the MetroCluster, switchover simulations fail

Example:

ClusterA::*> metrocluster operation show
       Operation: switchover-simulate
           State: failed
      Start Time: 2/19/2022 22:19:52
        End Time: 2/19/2022 22:19:57
          Errors: Failed to validate the node and cluster components before the switchover operation.
                  ClusterB::ClusterB-01 (non-overridable veto): DR partner NVLog mirroring is not online.
                  ClusterB::ClusterB-02 (non-overridable veto): DR partner NVLog mirroring is not online.

  • DR mirroring is also reported to be offline despite the FCVI device status being 'up'

ClusterA::> metrocluster interconnect mirror show
                          Mirror   Mirror
                  Partner Admin    Oper
Node Partner Name Type    Status   Status  Adapter Type   Status
---- ------------ ------- -------- ------- ------- ------ ------
ClusterA-01
     ClusterA-02
                  HA      enabled  online
                                           mlx4_0  IB     Up
                                           mlx4_0  IB     Up
     ClusterB-02
                  DR      enabled  offline
                                           fcvi_device_0
                                                   FC-VI  Up
                                           fcvi_device_1
                                                   FC-VI  Up
     ClusterB-01
                  AUX     enabled  offline
                                           fcvi_device_0
                                                   FC-VI  Up
                                           fcvi_device_1
                                                   FC-VI  Up

 