  • Brocade switches
  • FabOS releases:
    • FOS 8.2.3 or later
    • FOS 9.0.1 or later
    • FOS 7.4.2
    • FOS v8.2.2d4
    • FOS v8.2.2c6
    • FOS v8.2.1e1
    • FOS v8.2.1c5

Issue

  • Brocade SNMP process panic could lead to the following messages being displayed in errdump -a:

2021/10/07-09:34:37, Detected termination of process snmpd:xxxxx.
2021/10/07-09:34:37, First failure data capture (FFDC) event occurred.
2021/10/07-09:35:53, Detected termination of process snmpd:xxxxx.
2021/10/07-09:35:53, First failure data capture (FFDC) event occurred.
2021/10/07-09:35:53, Restartable daemon (snmp (pid=xxxxx)) died too soon. Reboot/Failover manually if necessary.
  • snmpconfig returns an error: 
> snmpconfig --show snmpv3
Failed to get snmp config info