Skip to main content
NetApp Response to Russia-Ukraine Cyber Threat
In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Apply failed for Object: igroup Method: baseline. Reason: Cannot create initiator group X because the initiator is a member of the initiator group Y with conflicting ostype

Views:
137
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

 

Applies to

  • MetroCluster
  • ONTAP 9

Issue

The configurations state of a Vserver in a MetroCluster is marked as degraded due to an ostype conflict from an initiator in an igroup belonging to the Vserver.

            Cluster : clusterA
            Vserver : vserver1
    Partner Vserver : vserver1-mc
Configuration State : degraded
      Stream Status : operation-failed
  Corrective Action : Resynchronize the configuration using "metrocluster vserver resync" command. Contact technical support for assistance if configuration-state does not change to healthy.
...
      Failed Reason : Apply failed for Object: igroup Method: baseline. Reason: Cannot create initiator group "igroup_windows" because the initiator "initiator1" is a member of the initiator group "igroup_vmware" with conflicting ostype "vmware".

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support