Ontap 9.1 and 9.2 System Manager unable to complete Remote Procedure Calls (RPC) due to Password length greater than 16 Characters

Views:
421
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • Ontap 9.1+
  • Ontap 9.2+
  • System Manager

Issue

Unable to delete a CIFS SVM via OnCommand System Manager web Interface
Data ONTAP API Failed: RPC Server remove failed for server "SVM_Name". Reason:
machine_account_remove: RPC: Can't encode arguments; netid=tcp fd=690 TO=25.0s
TT=0.000s O=68b I=0b CN=4977965/8 VSID=-3 127.0.0.1:765. (Error: 13001)


Note: The SVM can still be removed via Ontap Command Line Interface. 

 