Answer

Error finding prompt

  1. Command timed out
  2. Error Login to
  3. Error setting up shell channel

In this case, attempt to run the command that times out on a PuTTY/SSH session from the SANscreen acquisition unit.

The following commands are run when collecting data from a Brocade Switch when using the Brocade CLI data source which is available in SANscreen 4.5.5, 4.7.1, and 4.7.2 as a data source patch.

o alishow

o fabricshow

o fosconfig-show

o ipaddrshow

o nbrstateshow

o nsshow-t

o sfpshow

o snmpConfig--show accessControl

o snmpConfig-show mibCapability

o snmpConfig-show snmpv3

o switchshow

o switchstatusshow

o trunkshow

o version

o wwn -sn

List of queries that Perform makes via SNMP:

o connUnitPortStatCountInputBuffersFull

o connUnitPortStatCountFBSYFrames

o connUnitPortStatCountPBSYFrames

o connUnitPortStatCountFRJTFrames

o connUnitPortStatCountPRJTFrames

o connUnitPortStatCountClass3Discards

o connUnitPortStatCountRxOfflineSequences

o connUnitPortStatCountTxOfflineSequences

o connUnitPortStatCountInvalidCRC

o connUnitPortStatCountInvalidTxWords

o connUnitPortStatCountPrimitiveSequenceProtocolErrors

o connUnitPortStatCountInvalidOrderedSets

o connUnitPortStatCountFramesTooLong

o connUnitPortStatCountFramesTruncated

o connUnitPortStatCountAddressErrors

o connUnitPortStatCountDelimiterErrors

o connUnitPortStatCountEncodingDisparityErrors

o connUnitPortStatIndex

o connUnitPortStatCountTxElements

o connUnitPortStatCountRxElements

o connUnitPortStatCountLossofSignal

o connUnitPortStatCountLossofSynchronization

o connUnitPortStatCountInvalidCRC

o connUnitPortStatCountError

o connUnitPortStatCountRxObjects

o connUnitPortStatCountTxObjects

Additional Information