In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

EMC ECS data source fails performance collections in OnCommand Insight, with error: "Request failed with status 500"

Views:
19
Visibility:
Public
Votes:
0
Category:
oncommand-insight
Specialty:
oci
Last Updated:

Applies to

  • OnCommand Insight (OCI) 7.3
  • EMC ECS 3.5+ Data Source

Issue

  • Performance collections on an EMC ECS data source in OCI are failing with the following error:

Request failed with status 500

  • Review of the data source recording shows an error similar to the following in the sample log:

Caused by: com.onaro.sanscreen.acquisition.util.stream.http.JsonRestResponseException: Request failed with status 500 : https://{STORAGE_ADDRESS}:4443/flux/api/external/v2/query

  • Further review of the recording .dat file shows additional error context within the response payload:

{"error":"failed to compile query: validation failed: range 2h0m0s (start: 2022-03-08T17:41:11Z; stop: 2022-03-08T19:41:11Z) is longer than allowed 1 hour"}

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support