Effective December 3 - NetApp adopts Microsoft’s Business-to-Customer (B2C) identity management to simplify and provide secure access to NetApp resources. For accounts that did not pre-register (prior to Dec 3) access to your NetApp data may take up to 1 hour as your legacy NSS ID is synchronized to the new B2C identity. To learn more, Read the FAQ and Watch the video. Need assistance? Complete this form and select “Registration Issue” as the Feedback Category. 
NetApp Knowledge Base

What are the types of reboots and their differences on E-Series controllers?

Views:
862
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

 

Applies to

  • E2600
  • E2700
  • E2800
  • E5400
  • E5500
  • E5600
  • E5700
  • EF280
  • EF540
  • EF550
  • EF560
  • EF570

Answer

Soft Reboot
  • Only reboots the processor and is the default reboot method
  • Runs through firmware and does not issue a Power On Self Test (POST)
  • Command example:

reboot

Hard Reboot
  • Resets the entire board
  • Bypasses normal reboot hooks in the code
  • Runs through firmware and does not issue a POST
  • Command example:

sysReboot

Hard Power on Event
  • Only occurs when power is interrupted (power loss, powering off the controller)
  • Field Programmable Gate Array (FPGA) registers are reset
  • E-Series Controllers determine if a hard power on event occurred by checking the FPGA registers during Start-of-Day (SOD)
  • Issues a POST

Additional Information