Skip to main content
NetApp Knowledge Base

OCUM fails to monitor the cluster when one of the nodes is in uneligible state

Views:
413
Visibility:
Public
Votes:
0
Category:
active-iq-unified-manager
Specialty:
om
Last Updated:

Applies to

  • Active IQ Unified Manager (OCUM) 9.x
  • OnCommand Unified Manager (OCUM) 9.x

Issue

  • Cluster monitoring failed event it is displayed in the OCUM Web UI
  • The following error is present in the ocumserver.log
2020-08-12 05:57:04,193 ERROR [umadmin] [job-326] [refresh(cluster=%cluster_name%)|forceAcquisition] [com.netapp.dfm.job.JobEngine] Error executing job 929c0a0fc57e14bc:1c44b14f:173d8837f89:-7f9f task 929c0a0fc57e14bc:1c44b14f:173d8837f89:-7fa1: Errors reported on acquisition with start time 05:56:35.844: [storage-shelf-list-info; errno: 14007, reason: Node is not healthy, storage-adapter-get-adapter-info; errno: 14007, reason: Node is not healthy]
  • The following output is present in the ONTAP cli

cluster1::*> cluster show

Node                 Health  Eligibility   Epsilon

-------------------- ------- ------------  ------------

cluster1-a        true    true          true

fcluster1-b       true    true          false

fcluster1-c       false   false         false

cluster1-d        true    true          false

4 entries were displayed.

 