Issue

The following EMS log is reported when adding hard disk drives to a FAS system:

Disk %s cannot be used on a node configured as Flash Optimized.

The disk should be removed from the system.

The Sysconfig -a command reports the following output:

slot 0: SAS Host Adapter 0a (PMC-Sierra PM8001 rev. C, SAS, <UP>)
Firmware rev:       01.11.07.00
Base WWN:           5:00a098:0035310:20
Phy State:        [0] Enabled, 6.0 Gb/s
                  [1] Enabled, 6.0 Gb/s
                  [2] Enabled, 6.0 Gb/s
                  [3] Enabled, 6.0 Gb/s
QSFP Vendor:        Molex Inc.
QSFP Part Number:   112-00177+A0
QSFP Type:          Passive Copper 2m ID:00
QSFP Serial Number: 132720554

                  00.0 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.1 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.2 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.3 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.4 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.5 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.6 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.7 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.8 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.9 : NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.10: NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)
                  00.11: NETAPP   X302_HJUPI01TSSM NA04 847.5GB 512B/sect (Failed-Unsupported)

01.0 : NETAPP   X443_PLS15150A01 NQ10 142.8GB 520B/sect (66640)
01.1 : NETAPP   X443_PLS15150A01 NQ10 142.8GB 520B/sect (66645)
01.2 : NETAPP   X443_PLS15150A01 NQ10 142.8GB 520B/sect (66612)
01.3 : NETAPP   X443_PLS15150A01 NQ10 142.8GB 520B/sect (66621)
01.3 : NETAPP   X443_PLS15150A01 NQ10 142.8GB 520B/sect (66531)
Shelf 0: DS4246 Firmware rev. IOM6 A: 0173 IOM6 B: 0173
Shelf 1: DS4246 Firmware rev. IOM6 A: 0173 IOM6 B: 0173


The storage disk show command reports the following output:

Usable                 Disk           Container   Container
Disk                   Size Shelf Bay Type       Type        Name      Owner
---------------- ---------- ----- --- -------    ----------- --------- --------
1.0.0                     -    11   0 MSATA      Unsupported -         -
1.0.1                     -    11   0 MSATA      Unsupported -         -
1.0.2                     -    11   0 MSATA      Unsupported -         -
1.0.3                     -    11   0 MSATA      Unsupported -         -
1.0.4                     -    11   0 MSATA      Unsupported -         -
1.0.5                     -    11   0 MSATA      Unsupported -         -

The storage disk error error show command reports the following output:

Disk             Error Type        Error Text
---------------- ----------------- --------------------------------------------
2.3.0            persona-mismatch  The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.
2.3.1            persona-mismatch  The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.
2.3.2            persona-mismatch  The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.
2.3.3            persona-mismatch  The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.
2.3.4            persona-mismatch  The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.
2.3.5            persona-mismatch  The node is configured with flash optimized personality and this disk is not SSD. The Disk needs to be removed.